Saint NazaireMeat cold storage installation companyInvestment cost of the industry

632HP195506591   ·  2024-05-10 07:07:36   ·   energy

No matter whether the food cold storage or quick-frozen storage is in use, in the face of the above possible situations, we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However at present, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.Saint Nazaire,This high-quality CA library not only wants to bring a certain effect in use but also wants the hot air fan to reduce energy consumption in use. Every customer wants to achieve a better return with less investment. Therefore, today, I will introduce how the CA library can achieve energy-saving effect.The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following points: a low-temperature hall, a closed platform, an electric sliding refrigerated door, an anti-collision flexible seal and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.Hawsh Isa,Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, but it is necessary to grasp a certain limit and comprehensively consider the long-term energy consumption and initial investment, it is usually recommended that the number of thermostat refrigeratory outlets should be ~ square / ton.The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in - days, The library body can be combined, separated or increased or decreased according to the needs of users.Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, polyurethane does not produce harmful gas at high temperature.Building plan and other relevant data of cold storage construction project.Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.Direct labor,The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling,Saint NazaireInstallation of freezer,Saint NazaireFresh keeping quick freezing warehouse, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, with a spacing of mm and mm outside.


Saint NazaireMeat cold storage installation companyInvestment cost of the industry



Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor, and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.target,The refrigerant charge is insufficient. At this time,Saint NazaireInstallation price of quick freezing cold storage, just add enough refrigerant.Flow, temperature and water body of surface water around the construction area of surface water and water resources cold storage.Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.Saint Nazaire,For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.During the installation of long-span top warehouse plate, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate, and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted, the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate, so as to ensure that each lifting point can be installed at the same time during the installation of the top silo plate; The lifting point shall ensure that there are at least two points along the width direction of each warehouse plate.The exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.

0 Replies   |  until 2024-05-10 07:07:36 | 48 Views
Log inContent can only be published later