Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below degrees Celsius. Then, according to the volume of ~ grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.Belize ,The machine room shall be kept clean and well ventilated, and the condenser shall be cleaned and masonry removed regularly to ensure the normal and stable operation of the unit.The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below degrees Celsius. Then, according to the volume of ~ grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.Balpyk Bi,The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.Goods are imported and exported frequently and the throughput is large according to the requirements of production and operationProper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.


Belize How much does it cost to install a cold storageFree consultation



When opening and drilling is required for the top warehouse plate or wall plate,Belize Ice warehouse installation company, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole,Belize Which cold storage is installed, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.No dirt shall be accumulated on the equipment of the fresh-keeping warehouse, otherwise the warehouse plate of the frozen warehouse will deform and endanger the thermal insulation characteristics, and keep the channels around the frozen warehouse unimpeded. Only by ensuring excellent heat removal and refrigeration can it be excellent. The place where the freezer is placed shall be kept dry, clean, free of inflammables and ensure that there is no risk of cutting. Objects shall not be stacked in front of the air conditioning evaporator to prevent endangering the actual effect of refrigeration.The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.Marketing Department,Vent valve or water seal well shall be set at the outlet of flushing (thawing) drainage pipeline. Cold proof measures shall be taken for exhaust valves and water sealed wells in severe cold areas.Artificial refrigeration keeps the room at a constant temperature. The walls, the surface of the external wall of the cold storage is painted white or light color.Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator, the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.


Belize How much does it cost to install a cold storageFree consultation



Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.Installation materials, the reverse rotation indicates that the power wiring is reversed, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Belize , the butt joint shall be filled with foaming material,Belize Installation of freezer, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.

0 Replies   |  until 2022-04-21 00:05:03 | 78 Views
Log inContent can only be published later