LiperiFreezer manufacturerThe industry is facing development opportunities

632HP195506591   ·  2024-03-24 03:32:42   ·   energy

There are many application scenarios of cold storage, which are different. For a long time, it provides various cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, on-site settlement, honest operation,LiperiMedical cold storage, and has offices all over the country for long-term cooperation. Different purposes, so what needs to be understood in cold storage design?The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.Liperi, in the face of nature and for a long time, the condenser will be covered with a lot of dust and other foreign matters. These dust are firmly attached to the fins. If it is not handled manually, it is difficult to fall off. It can be diluted with cleaning agent according to a certain proportion, and evenly sprayed on the fins with a spray can. After waiting for minutes, it can be washed with clean water. If it is still not clean, the above can be repeated until the fins are clean.The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage,LiperiWhere does the cold storage installation sell, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in - days, separated or increased or decreased according to the needs of users.Lahore ,The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.The medical cold storage has been widely used in the industry. For the use of the medical cold storage project, we must combine the performance of the product and store it according to the temperature and humidity required by the product. The automatic temperature box also needs to be used outside the product cold storage. At the same time, the management personnel must be familiar with the operation steps of the medical cold storage project.During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.


LiperiFreezer manufacturerThe industry is facing development opportunities



Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Refrigerated vehicle planning Kende refrigeration reminds enterprises with the construction needs of logistics refrigerated warehouse project to conduct in-depth communication with the project and refrigerated vehicle planning on warehouse location and actual use needs when determining the final installation construction mode, so as to ensure the smooth circulation of goods in logistics refrigerated warehouse.Wall and floor fixtures shall start at corners. According to the plate layout drawing transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron,LiperiPrice of fruit preservation cabinet, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.Honest service,Fault phenomenon: high current or tripping during unit startup and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.If there is more air or refrigerant oil in the evaporator, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.


LiperiFreezer manufacturerThe industry is facing development opportunities



For cold storage, but its energy consumption is very large in the use of cold storage. How can we solve this problem?Customer first,Core tip: in the cold storage project, only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, and is not prone to failure, convenient use and management and long service life.The air suction surface of the condenser shall be kept more than mm away from the wall, and the air outlet shall be kept more than m away from obstacles.Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Liperi,At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage, you should install it from the corner first. Later according to the height of the cold storage, make a hole in the middle of the insulation board, and tighten the angle iron parts until there is a hole on the insulation boardThe construction of small cold storage is widely used in life, such as food industry, manufacturing industry, etc. since cold storage is so widely used, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.

0 Replies   |  until 2024-03-24 03:32:42 | 38 Views