ViborgHow much is the installation and construction cost of cold storageWhat are the components

632HP195506591   ·  2024-03-26 02:17:15   ·   energy

Application of parallel compressor in cold storage: the requirement of refrigeration capacity is large, and to refrigeration compressors under Malige need to be used on weekdays; Long term operation, large load peak valley difference and significant departmental load; Frozen and refrigerated objects are novel foods that are easy to decay and degenerate and have strict requirements for temperature and humidity.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.Viborg,When installing and splicing the storeboard in the fresh-keeping storehouse, it needs to be tightly sewn to ensure the tightness; The fresh-keeping storehouse will discharge water during operation, the fresh-keeping storehouse shall be equipped with emergency lights, alarm devices and safety channels to facilitate self rescue or alarm for help in case of emergencies.Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.Cabinda,Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.It will still decrease. The humidification amount will decrease by % at degrees.There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability but stainless steel plate has strong anti rust ability, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm,ViborgInstallation price of vegetable cold storage, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.


ViborgHow much is the installation and construction cost of cold storageWhat are the components



When hot ammonia defrosting or electric defrosting is selected as the cooling fan, professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, safety,ViborgInstallation of freezer, environmental protection and economy! The products are exported to foreign countries and are deeply trusted. Defrosting and drainage can be discharged immediately. Electric heat tracing and insulation can be selected for the defrosting and drainage pipeline of the warehouse location.The function of refrigeration is & amp; amp; ldquo; Low temperature storage & amp; amp; rdquo; Introduction & amp; amp; ldquo; Loop type & amp; amp; ldquo; Cold chain logistics & amp; amp; rdquo;Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.Create brilliance,General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse. - precautions for vertical plate of cold storage: vertical plate display


ViborgHow much is the installation and construction cost of cold storageWhat are the components



The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, which is slightly brittle at the initial stage, but generally disappears after a few days,ViborgInstall cold storage by yourself, and then maintains the stable performance of cold storage insulation materials for a long time.new product,In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.Fresh keeping storehouse is a building with artificial refrigeration to make the fixed space reach the specified temperature and facilitate the storage of goods. Fresh keeping warehouse wholesale can be widely used in food factories, dairy factories, factories, and so on. The following are the functions of the main parts of the fresh-keeping warehouse wholesale.When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Viborg,According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).

3 Replies   |  until 2024-03-26 02:17:15 | 26 Views

Shangke Packaging Materials Co., Ltd. 2024-03-26 11:17:20 support  0 | be opposed to  0

Good seller, thank you. My colleagues like ViborgHow much is the installation and construction cost of cold storage very much. Come again next time!

Filter and import and export business 2024-03-26 10:55:29 support  0 | be opposed to  0

I’ve been too busy lately, it’s too late to confirm, ViborgHow much is the installation and construction cost of cold storage is very good, like the boss.

Sales of our products and steel 2024-03-26 09:49:36 support  0 | be opposed to  0

Finally got ViborgHow much is the installation and construction cost of cold storage So happy that! The workmanship is great.