The flange surface is uneven, the tightening bolts are loose, and the installation and processing process is wrong, so that the bolts are not tightened well, resulting in oil leakage.Difference between dry-type transformer and oil immersed transformer:answer,The transformer manufacturer shall not use hand touch method to detect energized high-voltage equipment, such as transformer in operation and neutral grounding equipment of arc suppression coil. For the equipment without power supply and whose shell is reliable grounding device the temperature or temperature rise must be tested by hand. The secondary equipment can be inspected by hand touch method when it is hot and vibrated.Analysis of common faults of oil immersed transformer:Praia Grande,Avoid the load operation of power transformer: if the load operation is long-term it will lead to the scalding of solenoid coil, slow aging of insulation, two-color short circuit fault or short circuit to ground fault and dissolution of oil.The tap changer of power transformer shall also have strong insulation. kV off load tap changer is generally insulated from the ground by the produced insulating paper pipe factory.What is the wavelength of oil immersed transformer?
The bearing capacity of each load is different. Generally, dry-type transformer should operate under rated capacity, while oil transformer has better load working capacity.The step-up dry-type transformer refers to the instantaneous operation of voltage. At this stage, there are few manufacturers of dry-type transformer that can reasonably guarantee the instantaneous step-up in China. The step-up dry-type transformer has strong step-up capacity and good practical effect. The difference depends on that the transformer power switch without excitation regulator does not have the ability to change gear with load. Because this kind of tap power switch can cut off the whole process in a short time during the whole process of gear change, cutting off the load current will cause arc burning between circuit breakers, tap power on and off or short circuit fault, so the dry-type transformer shall be powered off during regulation. Therefore, it is generally used as a dry-type transformer that is not very strict in voltage regulation and does not need to be adjusted frequently.Common problems of tap changer of power transformerCredit guarantee,answerScb13-1600kva dry type transformer,& ldquo; of wiring transformer; Enter & rdquo; And & ldquo; Output & rdquo; Use a megger to test the grounding resistance between the terminal and the ground wire. When accurately measured by V megger,answerOutdoor energy-saving oil immersed transformer,answerIntelligent temperature controller for dry type transformer, the resistance value exceeds m ohm bus.Brief introduction of zero line of power transformerDry type transformer factory
After tightening the loose bolts, seal the flange, and solve the bolts that are likely to leak,Operation of oil immersed transformerThe proper selection of Anhui dry-type transformer has a key effect on improving the safety and smooth operation of power system software. In the above original text, we have already mastered the structure and characteristics of dry-type transformer. In this part, we will describe how to select dry-type transformer according to the load characteristics and application environment of dry-type transformer.The conductor insulation of power transformer is the main part of internal insulation. Some conductors should pass through the middle of electromagnetic coil, or between electromagnetic coil, iron yoke clamp and automobile oil tank wall. Therefore, it is necessary to ensure that this kind of conductor has sufficient insulation compressive strength, i.e. insulation spacing.answer,Oil leakage at electric welding positionNoise dispersion of dry-type transformerBrief introduction of zero line of power transformer
Installation of multimedia teaching equipment 2022-12-02 10:30:17 support 0 | be opposed to 0
road light pole 2022-12-02 09:34:32 support 0 | be opposed to 0
Industrial Machinery Parts 2022-12-02 10:01:32 support 0 | be opposed to 0
High and low voltage circuit breakers 2022-12-02 09:49:51 support 0 | be opposed to 0